C350 TRUSS ENGINEERING AND TRUSS PLACEMENT DRAWINGS.
All trusses shall be designed by a Washington State Registered Engineer. Engineer design truss submittal package and anchorage design shall be provided in accordance with Section 2303.4 I.B.C. 2015
Truss drawings, meeting the requirements of, and in accordance with 2303.4.1.1 shall be submitted. Truss placement diagram shall be provided in accordance with Section 2303.4.2. Permanent individual truss member bracing shall be in conformance with Section 2303.4.1.2 IBC
Truss members and components shall not be cut, notched, drilled, spliced or otherwise altered in any way without written concurrence and approval of a registered design professional. Alterations resulting in the addition of loads to any member (e.g., HVAC equipment, piping, additional roofing or insulation, etc.) shall not be permitted without verification that the truss is capable of supporting such additional loading. Section 2303.4.5 2015 IBC
Applied | Notice | 12/13/2020