A008 ACCESSIBLE ROUTE OF TRAVEL/CLEARANCE AT DOORS
Doors shall have minimum maneuvering clearances per Section 404 ICC/ANSI A117.1. For a hinge side approach, where a door must be pushed to be opened, provide minimum clearances as follows:
A. Where not equipped with both a closer and a latch, an unobstructed floor space, measured from the latch side, shall extend across the width of the doorway and beyond the hinge side of the door for a total width of not less than 54 inches; and at least 42 inches perpendicular to the doorway.
B. Where equipped with both latch and closer, an unobstructed floor space, measured from the latch side, shall extend across the width of the doorway and beyond the hinge side of the door for a total width of not less than 54 inches; and at least 48 inches perpendicular to the doorway.
Applied | Notice | 03/29/2022